Q & a on Common Faults of Parking Lot System_ Taigewang Technology

We may encounter some small problems in using the parking lot system, such as abnormal rise and fall of the gate, out of control of the remote control, etc. Here we summarize the problems encountered, hoping to help you. Question 1: when the gate rises or falls, it will stop after only a short distance. What's the matter? A: This is caused by the fact that the sensor of the gate motor does not sense the initial position signal sent by the controller. The solution is very simple. Continue to press the lever falling key on the remote control, press it several times until the lever falls in place, and then press the lever rising key to raise the lever in place. Repeatedly debug the lever rising and falling for several times, and the problem can be solved. Question 2: when the gate falls, it does not fall in place and stops. What is the reason? A: the first problem is caused by the lack of signal. This problem is caused by the dislocation of motor travel switch. At this time, it is necessary to open the shield of the main board of the gateway. There is a motor travel switch in the middle right of the main board. The motor for 6 seconds must be turned to the position of 6S (6 seconds). 3S for 3 seconds and 1s for 1 second. That is to match the configuration. Question 3: the gate rod is lifted in place. After staying for a few seconds, the gate rod will fall automatically. How can this be solved? A: at this time, it is caused by the failure of the automatic rod falling switch of the gate. The solution steps are as follows: 1. First eliminate the ground sensing factor and unplug the ground sensing detector. 2. Open the cover of the main board, and there are three sets of dial switches in the right position in the middle of the main board (the gate was not configured before 2011). Among them, 1 and 2 adjust the automatic rod falling delay, 1 and 2 have no delay when they are all off, and 3 is on, indicating automatic release. At this time, the rod falling signal will not fall. If the problem cannot be solved after the above reasons are eliminated, it should be caused by the chip failure of the motherboard. Please return the motherboard to our corresponding dealer for further treatment. Question 4: when using the remote control to control the gate, the gate motor does not respond, but the indicator light on the main board is normal. How to deal with this? A: there may be the following two reasons: 1. The motor is stuck; 2. There is a problem with the starting capacitor. The solution is as follows: open the upper cover of the gate and check whether the damping rubber pad is damaged. If the damage will cause the motor to get stuck, turn the shaft at the central position directly below the motor (with the help of external force or tools if necessary) to make the driving crank arm leave the stuck position. If the problem cannot be solved after step 1, the starting capacitor can be replaced to solve the problem. Question 5: the remote control can't control the gate, but the control by wire is normal. What's the reason? A: this may be because there is a problem with the remote control receiving circuit of the main board. The solution steps are as follows: make sure that the signal received by the main board is normal when the remote control is controlled. The indicator light is normal. At this time, the 9013 triode in the plug area of the main board remote control receiver can be replaced (generally available in the electronic market). If the problem cannot be solved, return the motherboard to the corresponding dealer for the next step. Question 6: how to use the road brake clutch correctly? Answer: the methods are as follows: 1. In case of power failure or the need to normally open the gate, make the gate lift lever in place, rotate the gate clutch to the [off] position with the clutch handle, and it is recommended to cut off the power supply of the gate at the same time. 2. When the clutch is closed, the remote controller can be used to rotate the gate motor. The active crank arm and the connecting rod coincide or form a straight line. At this time, pull the brake rod down by hand and rotate the clutch to the [closed] position at the same time. Question 7: when the gate falls, it will automatically bounce back if it doesn't fall in place. What's the reason? A: This is caused by the unbalanced spring tension. The solution is as follows: when the spring tension is relatively balanced, make the gate clutch leave. At this time, the rod can be stable at any position within the range of 40 degrees and 60 degrees. At this time, it is the best state. If the spring is unbalanced and the spring tension is large, the falling rod will rebound automatically if it is not in place. At this time, rotate the spring adjustment knob to the left (directly below the spring shield) until the spring tension is balanced. Experience: the weather in the north is cold in winter, so the spring tension can be appropriately adjusted to keep the gate in normal use. Question 8: the USB card issuer can't read the card. What's the reason? A: This is because the USB card issuer automatically starts the computer USB power saving mode after it is not used for a long time. The solution is very simple. Pull out the USB plug of the card issuer and plug it back in. Here, we suggest that if you do not use the card issuer for a long time, please unplug the USB interface, because some computers will save power for devices that are often not used.

Q & a on Common Faults of Parking Lot System_ Taigewang Technology 1

GET IN TOUCH WITH Us
recommended articles
Cases
no data
Shenzhen Tiger Wong Technology Co., Ltd is the leading access control solution provider for vehicle intelligent parking system, license plate recognition system, pedestrian access control turnstile, face recognition terminals and LPR parking solutions.
no data
CONTACT US

Shenzhen TigerWong Technology Co.,Ltd

Tel: +86 13717037584

E-Mail: info@sztigerwong.com

Add: 1st Floor, Building A2, Silicon Valley Power Digital Industrial Park, No. 22 Dafu Road, Guanlan Street, Longhua District,

Shenzhen,GuangDong Province,China  

                    

Copyright © 2024 Shenzhen TigerWong Technology Co.,Ltd  | Sitemap
Contact us
skype
whatsapp
messenger
contact customer service
Contact us
skype
whatsapp
messenger
cancel
Customer service
detect