There are two requirements for parking lot system wiring: one is standardized, safe and reliable, and the other is to strive for neat and beautiful wiring. Pay attention to the following points in the whole wiring process: 1. If the wiring is installed in the building, the cable shall be balanced or horizontal, and a sleeve shall be added outside to ensure the stability and beauty of the cable; 2. In order to avoid interference, 220V wires shall be laid separately from signal wires. They shall not be placed in the same pipe for convenience, and their spacing shall be more than 50cm; 3. All wiring must be sleeved, PVC or galvanized pipe can be selected to protect the cable from being bitten by rats; 4. If there is a breakpoint connection during wiring, it shall be welded with soldering iron and insulated; Wiring should be marked well, if debugging and maintenance is much simpler. The following is the specific wiring requirements of cable and signal wires. 1 220V power supply is required for cable entrance and exit gates and entrance and exit controllers. Three core shielded wire (rvvp3 * 1.5) is generally connected to special line ups for power supply. In some cases, AC220V power supply can also be connected nearby, but it shall comply with relevant specifications. It is necessary to ensure that the ground wire in AC220V socket in the system is truly grounded. 2 The networking mode of signal line parking lot can be divided into 485 communication, TCP / IP communication, RS422 communication, etc. the 485 networking line must adopt shielded twisted pair rvvsp2 * 0.5485 bus length, which can reach 1200 meters in theory, and it is recommended not to exceed 1000 meters. If it exceeds, please select 485hub or repeater to improve the communication environment. In order to ensure the stability of communication, connect the resistance at the end of the communication line, or connect all shielding layers, and the end can be suspended or connected to the earth according to the situation. 485 network must be bus structure, and all or partial star structure is not allowed. The TCP / IP networking line can select category 5 unshielded twisted pair, and the distance from the controller to the switch or hub should be less than 100m.
Shenzhen TigerWong Technology Co.,Ltd
Tel: +86 13717037584
E-Mail: info@sztigerwong.com
Add: 1st Floor, Building A2, Silicon Valley Power Digital Industrial Park, No. 22 Dafu Road, Guanlan Street, Longhua District,
Shenzhen,GuangDong Province,China