info@sztigerwong.com 86 0755-23773884

What if the camera can't log in?

Please make sure that the device and the login computer are on the same LAN; there is no IP conflict between the other devices and the device, and the IP conflict will cause login failure. The method of judgment is as follows: first disconnect the device, then ping the device IP on the computer to ping the instructions. If ping works, then this LAN IP is already in use.

Check and make sure that the network port indicator is on. If the indicator is off, the network is unreachable, causing the login to fail. In this case, check the network.


What need to do if forgetting IP address or user name and password?

Solved by hardware reset. Operation method: Open the outer cover of the device, there is a round hole on the black cover. Through the round hole, use the tool to press the reset button on the circuit board. After the LED of the device flashes twice, release the button, and the device can be restored after restarting to the default IP, username and password.


When setting up remotely, the result is another device set. What happened?

It may be that the IP addresses of multiple devices in the same LAN are duplicated. This is caused by IP address conflicts. Therefore, when multiple devices are used at the same time, be sure to set the IP address of each machine correctly to ensure that there is no IP address conflict.


What should I do if the device does not display properly?

The following conditions may occur: The device may not display properly: The device is not powered on properly; the network cable of the device is not connected properly, or the contact is poor; the IP address of the device and the IP address of the PC are not in an address segment; the device and the client The network between the two does not work.

Database log in failed solution

Database log in failed Solution: 

Open the software installation directory (default D:\ParkWatch) and select ParkWatch.ini, open it with notepad, configure it per the database installation FAQ 7 

DatabaseServer=USER-20181229C (database server name) 

DatabaseName=ParkWatch (database name, default ParkWatch)

 DatabasePath=D:\ParkWatchTGW\data\(Database storage path) 

SQLUser=sa (User name) 

SQLPassword=123456 (log in password)

Object name invalid

Object name invalid  


Step1: Open the software installation directory and select System.ocx to open with notepad. Select all (Ctrl+A) to copy (Ctrl+C) 

Step 2: Open the database, create a new query, select the database, paste (Ctrl+V), execute 

Step 3: Open the software again, the problem is solved, select the system administrator, login password default 666666